Applications
Emission monitoring
of pollution gases produced in industrial processes, monitoring and control of
flue gas desulfurization in applications such as:
Thermal power plant
Iron and steel
metallurgy plant
Industrial furnace, boiler
Cement plant
Petrochemical, chemical
plant
Heating boilers
Features
Certification
·
National production license for manufacturing
measuring instruments.
·
Environmental protection product certification.
Superior configuration
· Gas analysis using
MODEL 1080 analyzer.
· Particle
monitoring by laser light-scattering method.
· Temperature,
pressure, and flow monitoring using integrated configuration and transmitters
such as SIEMENS and ROSEMUONT and other world famous brands.
· According to the
requirements of environmental protection, the standard gas can be fed from the
sampling probe for system calibration.
Excellent stability and reliability
· Anti-corrosion
design of the whole system to ensure long term system reliability.
· Effective
anti-blocking method by which the sample probe will be cleaned by a high
pressure and high frequency air sweep (backflush), to prevent flue gas
contaminating the analysis components.
· Effective and
rapid cooling and drainage components, and a stable dew point to ensure the
measurement accuracy of system.
· Gas analyzer with
nichrome wire light source for a service life of up to ten years.
· Gas analyzer with
zero point auto-correction with negligible drift.
Easy maintenance and convenient operation
·
Modular design allows on-site replacement of the
module to shorten the maintenance down time.
·
Intelligent diagnosis and protection functions such
as self-diagnosis, control loss protection, fault alarms, etc.
·
Straightforward operation of interfaces with
text format menus.
System economy
·
Single point calibration of gas analyzer,
reducing the amount of standard material.
·
No dilution gas required, greatly reducing the
consumption of instrument gas.
·
Optional NH3 and TOC measurement to
improve the utilization of the whole system.
Technical parameters
Monitoring composition: SO2, NO, CO, O2
Detection
principle: NDIR: SO2, NO, CO, Electrochemical:
O2
Measurement range: SO2 0 - 500 ppm, 0 - 2500 ppm
NO 0 - 500 ppm, 0 - 2500 ppm
CO 0 - 500 ppm, 0 - 2500 ppm
O2 0 - 5 Vol %, 0 - 25 Vol %