MODEL 9830 Fe iron ion water quality online automatic monitor

MODEL 9830 iron ion water quality automatic monitoring instrument is developed by our company with completely independent intellectual property rights of automatic monitoring equipment and spectrophotometry instruments used to measure the concentration of iron ions in water. The instrument can be long-term unattended.

Applications

Petrochemical industry

Mineral processing industry

Chemical industry

Metallurgy industry

Electroplating industry

Wastewater treatment industry

Environmental protection related industries

 

Features

·         The instrument uses analysis methods, anti-interference ability, and is not affected by color.

·         Abnormal alarm and power loss will not lose data.

·         After reset and power-off, the instrument automatically excludes the remaining reagents in the instrument and automatically resumes working.

·         Automatic range switching function without manual setting.

·         With anti-control function, all functions of the instrument can be controlled by remote central control.

·         Set sampling time, interval, telemetry and other sampling methods.

·         The use of Panasonic imported PLC and other control components reducing environmental interference and equipment failure.

·         Uses sequential injection analysis, simple flow path, low reagent consumption and high degree of automation.

·         Self-developed multi-channel valve, high corrosion resistance, and long service life.

·         Powerful data storage capabilities up to 30,000 group years.

·         Convenient data export function, U disk direct export of historical data reports.

 

Technical parameters

Measuring range: 0 ~ 1000mg/l Fe2 +

Accuracy: ± 10% (indication error)

Repeatability: ≤5%

Measurement cycle: minimum measurement cycle 35min

Measurement interval: interval mode (1 ~ 9999) min, external control mode, the whole point mode (24 hours arbitrary setting)

Calibration method: manual/automatic mode

Service Interface: RS232 or RS485

Display: color touch screen

Operation menu: Chinese

Data storage: 30,000

Analog output: (4 ~ 20) mA

MTBF: ≥720h/time

Power: (220 ± 22) V AC, (50 ± 1) Hz

Size: 1600mm × 600mm × 600mm